| Management number | 218558481 | Release Date | 2026/05/03 | List Price | $12.79 | Model Number | 218558481 | ||
|---|---|---|---|---|---|---|---|---|---|
| Category | |||||||||
1. Input point X x0-x7, DC24 input, low level valid. X0-5 is the high-speed counting input port (default: 12K,100KHZ optional). 2. Output analog voltage WR3A instruction, corresponding to the value 0-4095. 3. The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y. 4. Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A. 5. Intermediate relay M: M0-M3071, the power loss preservation range can be set. Specification: Features: Input point X x0-x7, DC24 input, low level valid. X0-5 is the high-speed counting input port (default: 12K,100KHZ optional). Output analog voltage WR3A instruction, corresponding to the value 0-4095. The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y. Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A. Intermediate relay M: M0-M3071, the power loss preservation range can be set. Specification: Weight: 239g/8.4oz Input point:8 Output point:6 Power supply voltage: DC24V Output current: 5A Analog input: 6AD Analog output: High speed count:6 road 12K optional 100K Pulse output: No Floating point: Support Step motor: No support Memory capacity:8000 step Programming software: GX developer or GX works Program steps: 8000 steps Two communication ports: One RS232 (DB9) serial communication port is FX3u protocol 38400,7, E, 1; One RS485 (485 optional configuration) (communication protocol can be set to D8120). The output point Y : Y0-Y5 is optional relay or transistor output, relay output current 5A. The transistor output DC24V, the current maximum 1A. Y0-1 is high-speed output port (maximum 100K). PWM period is 0-32767US. High The maximum speed current is 1A. External load common terminating + 24, the other end received the PLC output port Y. Analog input: Six-way analog input,12 bit accuracy, input voltage:0-10V,0-20MA; Read the analog quantity with directive. The corresponding values 0-4095. Two-way potentiometer analog input, D8030, D8031. Analog output: 2-channel analog output, 12-bit accuracy, output voltage: 0-10v. Output analog voltage WR3A instruction, corresponding to the value 0-4095. Intermediate relay M: M0-M3071, the power loss preservation range can be set. Step point S: S0-1023, power off storage range can be set to S0-S1023 100Ms timer: t0-t199, accumulative power off save t184-t199 10Ms timer: T200-T249, accumulative power off saving T246-T249 1Ms timer: T250-T383, where T250-255 is cumulative 16-bit counter: C0-C199, power off to save C100-199 32-bit counter: C200-C219, power off to save C220-C234 32-bit high-speed counter: C235-255; C235-240 is a single-phase counter, not frequency doubling; C241-240 is a single-phase counter with double frequency; C247-249 is a two-phase counter, not frequency doubling; C250-252 is a two-phase counter with double frequency; C253-255 is a two-phase counter, 4 times frequency; Register D: D0-D7999, power off save range can be set to d0-7999, Indirection pointer V, Z: V0-7, Z0-7 P subroutine number: P0-63 I interrupt: X0-5 external interrupt. Timer interrupt (1MS). The counter is interrupted. Special M components: M8000 is normally closed when running, M8002 is electric pulse, M8011 is 10Ms pulse, M8012 is 100Ms pulse,M8013 is 1s pulse,M8014 is minute pulse. Package List: 1x PLC Control Board
| Brand Name | OPPWONG |
|---|---|
| Part Number | OPPWONGnf86p2curx |
| Manufacturer | OPPWONG |
| Included Components | no |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form